The AC wiring and making a 240VAC outlet work with a 120VAC inverter
In the RV or motorhome world, whenever you plug into the grid to get
power we say you are plugging into "shore" power. This term comes from the
boating world where you plug in when you get to shore (land.)
This motorhome accepts either 120 volts (V) AC or 240V,
at 50 amps. The problem with this system was that the Outback 2012
inverter takes only 120V and puts out only 120V (i.e. never 240V.)
Also, the inverter's maximum input and output
is only 30 amps. So somehow I had to make this all work even when the
shore power is 240V.
Here's how the wiring worked in this motorhome before changes were made.
- AC wiring diagram before rewiring -
 |
|
The thing to realize is that all the breakers in the breaker panel and
hence all the loads in the motorhome are 120V. The breaker
panel doesn't even allow a 240V appliance. There's no way to put in
a breaker that is connected to both L1's power bar and L2's power
bar at the same time, unlike with breaker panels in houses which
do provide a way.
So the solution to make it work with the inverter was simple.
For the input to the inverter from shore power, I took L2 and
neutral and sent those to the inverter. For the output from
the inverter I sent this to the breakers that L2 had previously
powered. Meanwhile, I left L1 unchanged.
- AC wiring diagram after rewiring -
 |
|
As shown at bottom/left in the above wiring diagram, when connected to shore power,
the Outback inverter passes thru the
shore power directly to the output (1, 2, 3, 4), using any leftover to charge
the batteries as needed (1, 2, 5). When not connected to shore power, the inverter
converts DC power from the batteries to AC power to feed to the output (5, 3, 4),
i.e. it's inverting.
That means that the breakers previously powered by L2 would get
their power from shore power when the motorhome was plugged into
shore power and would get their power from the inverter when the
motorhome was not plugged into shore power (e.g. when it was on
the road). This also means that the breakers powered by L1 would
get power only when plugged into shore power (6). When not plugged
into shore power whatever loads were connected to the L1 breakers
would not work. This was actually the case for all the breakers before
this solar system was installed.
This also addressed the 30 amp maximum output issue with the inverter.
Since the inverter would only ever power the L2 half of the breaker panel
it would never be asked to supply more than 30 amps.
Notice that the neutral wire has been split into two independent
wires that both go to the inverter. This is a special requirement of
the mobile versions of the Outback inverters.
The inverter bypass switch (bottom/right in the above wiring diagram) allows the
inverter to be removed from the circuit in case the inverter breaks down.
It puts things back the way they
were before. It consists of two breakers that work together. Notice that the
left one is upside down, so for it, up is OFF and down is ON. This is
just the opposite of the right breaker. The above diagram shows the normal
position with the left breaker OFF and the right breaker ON, meaning that
the output of the inverter is going to the breaker panel. If it were in the
down position then the left breaker would be ON and the right breaker would
be OFF, meaning shore power would be going directly to the breaker panel.
- Wiring between the E-Panel and the inverter.
 |
|
- The junction box (see AC wiring diagram above.) -
 |
|
- The AC wiring done in the E-Panel. -
 |
|
- The AC wiring route through the RV. -
 |
|
Wiring the Outback turbo fan for sealed inverters
The Outback FX2012MT inverter is a sealed inverter and comes with a fan in the
cover that has to be wired up. The difficulty is that the fan is embedded in
the metal cover and the wires go in the AC wiring compartment. This is difficult
because the AC wiring compartment cover is partically under the metal cover.
So you need to connect the wires in the AC wiring compartment while holding on
to the metal cover, then screw on the AC wiring compartment cover and then
screw on the metal cover.
The fan is a 12 volt DC fan. The negative (black) wire goes to the AUX- port
and the positive (red) wire goes to the AUX+ port. The inverter's default setting is
to use the AUX port for the fan so no programming is needed, though I always
check. This is done from the Outback Mate after everything has been installed
(the inverter runs off of the batteries so you'll need to get at least that
far before any programming can be done.)
The battery bank, battery temperature sensor and venting
The batteries were 8 Trojan T-105 Plus deep cycle flooded lead acid batteries. They
are 6 volts each with a capacity of 225 amp hours (AHr) at the 20 hour rate. This
means that they will deliver 225 amps total if discharged over 20 hours.
Since the Outback FX2012MT inverter is a 12V inverter, I had to wire
the batteries together to make up a 12V battery bank. To start with,
each battery is 6V. Just like with solar panels, connecting batteries
in series (positive to negative) causes the voltage to add while the
current (AHr) stays the same. So I connected the positive of one
6V, 225AHr battery to the negative of another 6V, 225AHr battery to
end up with a 12V, 225AHr series string of batteries. That gave me
my 12V. So I repeated this with the remaining 6 batteries giving me
4 separate 12V, 225AHr series strings. Since connecting them further
in series would give me too high a voltage, all that was left was to
connect these strings
in parallel. Connecting in parallel leaves the voltage the same but
the current (AHr) adds. So now I had 4 parallel connected strings
for a total battery bank size of 12V, 900AHr (4 x 225). Unfortunately
I was too busy installing the system to remember to take a photo but
the following diagram illustrates what I did.
- Battery wiring diagram. -
 |
|
All the very thick grey cables shown above are 4/0. 4/0 is about 12mm (1/2") in
diameter. It needs to be around that thickness in case there is a short
in the battery wiring somewhere. If a 900AHr battery bank starts dumping
due to a short then the current could be hundreds of amps so thick wiring
is need to handle that current without melting and starting a fire.
The inverter - battery disconnect switch is a 250 amp DC breaker. Besides safety,
it's also used to disconnect power from the inverter since the inverter runs
off of battery power (the Outback inverter will also run off shore power if shore
power is connected when this inverter-battery disconnect switch is turned off.)
The temperature sensor is glued (and I also strapped it) to the side of
a battery somewhere in the middle of the battery bank. It gives the inverter
some idea of the temperature of the batteries so that it can compensate
appropriately when charging.
Also of note above is the way the battery bank's negative terminal is
grounded. This is done indirectly using the green thick 4AWG wire in
the E-Panel between the shunt's busbar and the ground bar (see wiring
diagram above.) Theoretically the wiring in the path to ground for
the batteries should be the size of the largest wire used in the batteries,
4/0, which is about 12mm (1/2") thick. This is a little unreasonable and
so the Ontario Electrical Code says it would be safe enough to use
at least 4AWG wire.
Lastly, note the CAT5e communication cable connecting the inverter to
the Outback Hub. This is so that the inverter can be monitored and controlled
from the Outback Mate which I installed on a wall inside the motorhome's
living area.
- DC wiring between E-Panel and inverter plus BTS and Hub. -
 |
|
- DC wiring in the E-Panel and entry to battery box. -
 |
|
- Customer built battery box. -
 |
|
- The battery box in place. -
 |
|
Unfortunately I don't have a good enough photo but the cover for the battery box that
the customer made had a hole in the front left corner for venting (see photo below.)
Batteries that are being used to power loads or are being charged produce
hydrogen, the heavier the use the more the hydrogen. This hydrogen must
not be allow to accumulate otherwise a spark
might set it off, causing an explosion. A 2 inch flexible hose was run
from the hole in the battery box cover, through the wall between this
compartment and the adjacent small battery compartment, to an existing grill
(see photo below.)
The four holes in the bottom front of the battery box are necessary to allow
fresh air in (see photos above.) At the same time as the batteries are generating
hydrogen, they also generate heat, heating the air in the battery box.
Since hot air rises it will rise into of the vent hose in the top of the
cover, pulling fresh air in from the four holes in the bottom front.
In one of the above photos you can see the cables and temperature sensor
wire entering the battery box on the side near its top. Since I didn't
want hydrogen coming out of here I sealed the gaps in this hole with
silicon caulking.
The box was wedged into the storage compartment snuggly with angle iron
at its base. From the above photo on the left you can see spacers that
keep that batteries from moving around much, though they are not perfectly
snug. Air does have to be able to circulate around the individual batteries
to prevent them heating up too much.
- Venting the battery box. -
 |
|
Prev -
Page 1,
2,
3,
4 -
Next