NOTE: Clicking on any link in the body portion of this page will take you to a new window or tab so that you don't lose any information.

The next step is to figure out which solar panels (also called solar modules) you need and how many. For an off-grid system you'll likely need more than one solar panel. The collection of all your panels is referred to as your solar array.

Fill in the following and click on the Calculate button...

Item 1. Insert your watt hours needed per day. This is the value you got from Step 1, Part C in working out your power needs.
Watt hours needed per day: (Wh/day)

Item 2. Enter the voltage across your entire solar array.
Solar array voltage: (V)
This is a first guess at how many volts will be across the wires coming from your solar array. As you refine your design this value will become more certain. It's selected based on a few possible factors:
1. Your charge controller may be able to handle only a certain set of voltages from your solar array, so if you already have a charge controller in mind then choose a voltage from its list of input voltages. The actual voltage will be calculated and given below in the Result section.
2. The current from the solar array affects the thickness and cost of the wires coming from the solar array - the higher the voltage the cheaper/thinner the wire. Item 1 below the calculator talks more about that.

Typical values to start with are around 12, 24 or 48, the larger the system the higher the value and 100 isn't unusual for a large system. If you don't know then enter 24 for now. But once you've shopped around for charge controllers or gone on to the step to find out your wire size, you'll likely come back and change this value.

Item 3. This is the average number hours per day you get full sunshine. Select this for the season which you'll be using your off-grid system. For example, for a summer cottage use the average sunshine hours per day during the summer. For a year round location use the average sunshine per day for the year.
Bright sunshine hours per day: (h/day)

Item 4. This one is tricky since you may not have chosen a specific solar panel yet. But this is when you have to start looking for one. You may later change your mind and have to try a different one and come back to this.
On the back of the solar panel, or on the specification page which you find online or have in paper form, there is a value for the Maximum power current (Imp or Impp). That's what you put here. See below for more about these specifications.
Solar panel maximum power current: (A)

Item 5. Just as with the current you entered above, this is on the back of the solar panel, or on the specification page which you find online or have in paper form. There should be a value for the Maximum power voltage (Vmp, Umpp, ...). That's what you put here. See below for more about these specifications.
Solar panel maximum power voltage: (V)



Result:
The number of solar panels needed is : parallel strings, each string of panels containing in series.
The voltage of the solar array will be V ( in series x ) but 25% is added to this since that value is for 25°C (standard test conditions) and actual temperatures may be colder at times (solar panels are more efficient when colder), giving a solar array voltage of V. Your charge controller should be rated for this.
The current on the wires coming from the solar array will be A (amps) ( parallel strings x ) but 25% is added to this due to sources of reflected sunlight (lakes, snow, clouds) giving a current from the solar array of A (amps) as input. Your wires, breaker/fuse, and charge controller should be rated for this. This is 2% of an AHr (amp hour) battery bank ( /0.02).

Solar panel specifications

Solar panels are specified by a few values which can be found on a label on the back of the solar panel (see photos below) or by searching on the internet for the panel's manufacturer and model number. The values are obtained under certain standard test conditions (at sea level, a certain temperature and amount of sunlight) and will not reflect what you'll actually get at all times.

Front and back of a solar panel, or solar module, and the label with the specifications on the back of the module.
Front and back of a panel, and the label on the back. (Note that this is not the one used for the examples below.)

The important values are:

Short circuit current (Isc) and open circuit voltage (Voc) diagram.
Short circuit current and open circuit voltage.
  • Short circuit current (Isc) - This is the current when both ends of a solar panel are directly connected together. In the diagram above there is no load in this case; the two output wires in the back of the solar panel are connected to each other.
    The "I" in Isc stands for intensity and is an old word for current. The "sc" stands for short circuit, which is what it's called when the two wires of an electrical circuit are connected together with no load in between.
  • Open circuit voltage (Voc or Uoc) - This is the voltage measured when nothing is connected to the solar panel i.e. no electrons are flowing, there is no current. In the diagram above the two output wires in the back of the solar panel are both not connected to anything. A solar panel's voltage is at a maximum when there is nothing making demands on it, or in more technical terms, when there is nothing drawing current from it.
    The "V" or "U" in Voc or Uoc stand for volts and "oc" stands for open circuit, the circuit is open with nothing in between the two ends.
  • Maximum power current (Imp or Impp) - This is the current the panel has available when the panel's power output is at a maximum under certain standard sunlight and temperature conditions. See immediately below this list for more about this.
    The "I" stands for intensity and is an old word for current. The "mp" or "mpp" stand for maximum power or maximum power point.
  • Maximum power voltage (Vmp, Umpp, ...) - This is the voltage the panel produces when the panel's power output is at a maximum under certain standard sunlight and temperature conditions. See immediately below this list for more about this.
    The "V" or "U" stands for volts and "mp" or "mpp" stand for maxium power or maximum power point and there can be other variations of these letters.
Maximum power current, maximum power voltage and maximum power graph.
Maximum power point graph.

Maximum power current and maximum power voltage are related and exist at the same time, when the power is at a maximum (see the graph above.) That's because the power is equal to the current multiplied by the voltage:

Formula for power, power = current x voltage.

So when the product of the two is the highest it can be, that's when you have maximum power. As the graph shows, it's not when the current is at a maximum (that's Isc) and not when the voltage is at a maximum (that's Voc). Maximum power current and maximum power voltage happen when what you get when they're multiplied together (the product) is at a maximum, when the power is at a maximum. That's why they're not called maximum current and maximum voltage, but maximum power current and maximum power voltage instead.

Understanding the above solar array size values

How series strings for solar arrays works.
Series strings.
How parallel for solar arrays works.
Parallel.

In the diagram on the right, the values shown in the rectangles that represent individual solar panels are the maximum power voltage and the maximum power current.

Your solar array is made up of some number of series strings connected in parallel. These terms were covered when you sized your battery bank but are worth repeating here.

Connecting solar panels in series means connecting the positive of one panel to the negative of the next panel, and so on, as shown on the right. A set of panels connected in this way is called a series string, or just a string. When you do this, the voltages of all the panels in the string are added up to get a larger voltage. The total current is the same as for a single solar panel. So if you need a higher voltage output from your solar array then you'll be connecting more panels together in series.

Connecting solar panels in parallel means connecting the positives together and the negatives together. When connecting series strings of panels together, only the positives at one end of the strings are connected together and the negatives at the other end of the strings are connected together. The diagram on the right shows this. When you do this, the total current is equal to the current for one solar panel multiplied by the number of strings that are connected together. The total voltage is the same as for a single series string.

Our example

We start out with the watt hours needed per day from the working out your power needs page, 2922 Wh/day. The suggested voltage to start with is 24 volts. In our area I happen to know we get an average of 3 hours of sunshine per day on a year round basis. Shopping around, I found a solar panel whose Maximum Power Current is 8.15 amps and whose Maximum Power Voltage is 28 volts. So my starting values are:

Example 1a solar array parameters for sizing solar array.
Example 1a solar array parameters for sizing solar array.

Entering the above in the calculator and clicking on the Calculate button tells us that the solar array voltage will be 35V and that the current on the wires from the solar array will be 50.94amps. We then go to the voltage drop calculator and enter the following parameters:

Example 1a wire sizing parameters for sizing solar array.
Example 1a wire sizing parameters for sizing solar array.

The voltage drop calculator tells us that for 50.94amps we will require a wire size of 2 gauge (AWG), which is much too expensive. So we go back to the above solar array calculator and increase the Solar array volage to 72 V, entering the following parameters:

Example 1b solar array parameters for sizing solar array.
Example 1b solar array parameters for sizing solar array.

As a result of that we are told that the solar array voltage will be 105 V and that the current on the wires from the solar array will be 20.38 amps. Going back to the voltage drop calculator and with the new voltage and current we enter this:

Example 1b wire sizing parameters for sizing solar array.
Example 1b wire sizing parameters for sizing solar array.

This time the voltage drop calculator tells us the wire needs to be 8 gauge (AWG) which is more affordable.

So the result is that we need of 6 solar panels. We'll wire them as 2 series strings with 3 panels in each string. Then we'll connect the 2 strings in parallel. This is the same as the parallel example in the above diagram. Also, the wire between the solar array and the charge controller will be 2 40 foot lengths of 8 AWG insulated wire, one for the positive and one for the negative. We'll of course either need to run a ground wire, also 8 AWG, or hammer a ground rod into the ground at the array.

Some items to consider

At this point there are some items you need to look at that may cause you to change the above values.

Item 1. Is the current on the wires from the solar array too high?

One of the last values calculated and shown near the bottom above is the current that will be on the wires going from the solar array to the charge controller. This is usually two or more very long wires, maybe going from the roof to the basement or from the base of a pole, then underground in conduit and then into the basement. The higher the value you get for this, the thicker that wire will have to be. And copper wire is expensive so you want it to be as thin as possible.

You can get some idea of how thick this wire will need to be by using this wire sizing/voltage drop calculator.

Once you know the thickness of wire you can shop around. If the price is too much then redo the above calculation starting with a higher Solar array voltage. If you went through the above example, you'll see that we did just that.

Item 2. The current on the wires from the solar array must be at least 2% the battery bank capacity

As with item 1 above, this involves the current that will be on the wires going from the solar array to the charge controller. A battery just sitting idle will lose 2% of its charge per day. Your solar panels must therefore provide enough current to keep it topped up. In other words, the current coming from your solar panel must be at least 2% of your battery bank's capacitiy. In Step 2, the battery sizing calculator, you calculated your battery bank's capacity. To help you make sure that the solar array you came up with above provides at least 2% of the needed current, the size of a battery bank that your solar array's current is 2% of is given as one of the outputs of the calculator above. If that value is larger than your battery bank capacity then you're okay. If not, then you'll have to start the form above with a larger Watt hours needed per day until the battery bank capacity calculated above is larger than your battery bank capacity. Most often this isn't an issue.

Item 3. Your charge controller must handle an extra 25% amps

A lake, snow and clouds all reflect extra sunlight onto your solar array. It's as if there are extra suns in the sky. As a rule of thumb we add an extra 25% to the current that will be on the wires going from the solar array to the charge controller. This becomes the amount of current that your charge controller will need to be able to handle as input and is a value to consider when shopping for your solar panel. The value for this has been calculated at the bottom of the above calculator.

The end result for step 3

You now know which solar panels you'll need, how many and how you'll configure them (series/parallel). In figuring that out you've probably already figured out what size wire you'll need between your solar array and the charge controller. Click on an icon at the top or bottom of this page to go to another step.

NOTE: Clicking on any link in the body portion of this page will take you to a new window or tab so that you don't lose any information.

More topics

rimstar.org - Share your project on rimstar.org - About - Privacy policy - © 2020 Steven Dufresne
Contact: